Implementation of Radiant Cooling System in Floors
DOI:
https://doi.org/10.53555/mce.v3i4.524Keywords:
energy crisis, alternative, Radiant cooling, cooling waterAbstract
Taking energy crisis into consideration many researches are going on in alternative sources in the fields of Automobile, Refrigeration and Air Conditioning, Oil and Gas Industries. Radiant cooling system is such a type of alternative source used in the field of Air conditioning systems. Radiant cooling system can be implemented in floors, ceilings and pillars of multi storey buildings. We have implemented radiant cooling system in floors. With this system surrounding surface temperatures are lowered by
absorbing the sensible heat from the conditioned space providing thermal comfort to the occupants in the room and this is made by circulating cooling water in the floors through copper/ aluminium tubes.
Downloads
References
The Performance of Thermal Radiant Cooling System Arun Kumar Kulhari1, Suveg Singh2 & Dr. Rahul Goyal3.
Radiant cooling systems for high performance buildings AR.SHIKHA AGGARWAL* Architect, Associate Professor, University Institute of Architecture, Chandigarh University Punjab, India.
Radiant Floor Cooling Systems Bjarne Olson, Ph.D.,,” ASHRAE Journal, September 2008.
Experimental study of space cooling using ceiling panels equipped with capillary mats France, 2007 Catalina T. and Virgone J.
Design of a Radiant Panel Cooling System for Summer Air Conditioning System September-2014 Mohamed E.T. & Abdalla N. K .
Catalina T., “Evaluation of thermal comfort using combined CFD and experimentation study in a test room equipped with a cooling ceiling”, BUILDING AND ENVIRONMENT AUGUST 2009.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2017 gnpublication@
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
In consideration of the journal, Green Publication taking action in reviewing and editing our manuscript, the authors undersigned hereby transfer, assign, or otherwise convey all copyright ownership to the Editorial Office of the Green Publication in the event that such work is published in the journal. Such conveyance covers any product that may derive from the published journal, whether print or electronic. Green Publication shall have the right to register copyright to the Article in its name as claimant, whether separately
or as part of the journal issue or other medium in which the Article is included.
By signing this Agreement, the author(s), and in the case of a Work Made For Hire, the employer, jointly and severally represent and warrant that the Article is original with the author(s) and does not infringe any copyright or violate any other right of any third parties, and that the Article has not been published elsewhere, and is not being considered for publication elsewhere in any form, except as provided herein. Each author’s signature should appear below. The signing author(s) (and, in